Τετάρτη 19 Δεκεμβρίου 2018

Noninvasive continuous arterial pressure monitoring with Clearsight during awake carotid endarterectomy

BACKGROUND Continuous noninvasive blood pressure (CNBP) measurement using the volume-clamp method is a less invasive alternative compared with invasive intra-arterial monitoring for awake patients during carotid endarterectomy (CEA) under regional anaesthesia. OBJECTIVE We investigated the agreement of blood pressure (BP) recorded with invasive and CNBP methods during awake CEA. DESIGN A prospective observational study for assessing agreement with Bland–Altman plots, agreement-tolerability indices (ATI), concordance and interchangeability. SETTING Azienda Ospedaliera Universitaria G. Martino, Messina, a University tertiary referral centre in Italy. PATIENTS In 30 consecutive patients, we recorded continuously ipsilateral invasive and noninvasive BPs, from 3 min before carotid cross-clamping to 5 min after unclamping. MAIN OUTCOME MEASURES Primary outcome was bias, 95% limits of agreement, ATI, concordance and interchangeability for mean arterial pressure (MAP). Secondary outcomes were agreements for systolic arterial pressure and diastolic arterial pressure. Tracking of changes was assessed with four-quadrant polar plots and the trend interchangeability method. Optimal bias was defined as 5 mmHg or less. RESULTS A total of 2672 invasive and CNBP paired measurements (93% of overall data) were analysed, with a median of 92 readings per patient [IQR 76 to 100]. Mean (SD) bias for MAP, systolic arterial pressure and DAP were −6.8 (6.7), −3.0 (9.7) and −9.0 (5.4) mmHg, respectively. The ATIs were 0.88, 0.95 and 0.71, respectively, where ATI of 1.0 or less and at least 2.0 defined acceptable, marginal and unacceptable agreements. The four-quadrant plot analysis for beat-to-beat differences showed concordance rates of 97.3%, 99.98% and 96.4%, respectively. Polar plot analysis showed 95% limits of agreement of −3 to 3, −2 to 2 and −2 to 2 mmHg respectively. Trend interchangeability method showed an interchangeability rate of 95% for MAP. CONCLUSION During CEA performed under regional anaesthesia, CNBP offers a less invasive approach for BP monitoring. We found acceptable agreement for MAP defined by an ATI of 0.88 and an excellent 95% global interchangeability rate. A suboptimal bias of 7 mmHg was found with CNBP for MAP. Correspondence to Alberto Noto, Department of Anaesthesia and Intensive Care, Messina University, Messina, Italy Tel: +00 39 3471981248; e-mail: alberto.noto@unime.it © 2018 European Society of Anaesthesiology

https://ift.tt/2SbX1Vg

Local infiltration anaesthesia versus sciatic nerve and adductor canal block for fast-track knee arthroplasty: A randomised controlled clinical trial

BACKGROUND Local infiltration anaesthesia (LIA) was introduced as an innovative analgesic procedure for enhanced recovery after primary total knee arthroplasty (TKA). However, LIA has never been compared with analgesia based on an adductor canal catheter and a single-shot sciatic nerve block. OBJECTIVE To evaluate two analgesic regimens for TKA comparing mobility, postoperative pain and patient satisfaction. DESIGN Two-group randomised, controlled clinical trial. SETTING Charité-Universitätsmedizin Berlin, Campus Charité Mitte, Germany between April and August 2017. PATIENTS Adults undergoing primary TKA under general anaesthesia were eligible for study participation. Exclusion criteria were heart insufficiency (New York Heart Association class >2), liver insufficiency (Child Pugh Score >B), evidence of diabetic polyneuropathy, severe obesity (BMI > 40 kg m−2), chronic opioid therapy for more than 3 months before scheduled surgery and allergy to local anaesthetics. INTERVENTIONS Nerve block patients group (n=20) underwent surgery with two ultrasound-guided regional anaesthesia blocks: a single-shot sciatic nerve block with 20 ml of ropivacaine 0.75% combined with an adductor canal block with a catheter placed for less than 4 days with an infusion of ropivacaine 0.2% at a rate of 6 ml h−1. LIA patients (LIA group, n=20) received LIA of the knee capsule at the end of surgery with 150 ml of ropivacaine 0.2%. MAIN OUTCOME MEASURES The primary endpoint was postoperative time to patient mobilisation (ability to walk) on the ward. RESULTS Baseline characteristics were similar in each study group. Patients in both groups were mobilised to walk after TKA in similar time frames (LIA 24.0 h versus nerve block 27.1 h, 95% CI of difference −9.6 to 3.3 h). Maximum postoperative pain scores on exertion were higher in LIA patients with a mean 1.3 of 10 numerical rating scale points (95% CI 0.3 to 2.3, P = 0.010) as were intra-operative opioid requirements (LIA median 107 [IQR 100 to 268] mg versus nerve block median 78 [60 to 98] mg, P 

https://ift.tt/2A8UunD

Τρίτη 18 Δεκεμβρίου 2018

Evaluation of lung transplant perfusion using iodine maps from novel spectral detector computed tomography

p. 436
Nils Große Hokamp, Amit Gupta
DOI:10.4103/ijri.IJRI_35_18  
We report the case of a 51-year-old patient who underwent bilateral lung transplantation and presented with an unstable condition and sepsis 6 days after transplantation. The performed contrast enhanced spectral detector computed tomography (CT) using a dual-layer detector showed absence of perfusion in the left lung on iodine maps, although branches of the pulmonary artery were patent. This prompted retrospective evaluation of CT images and total venous occlusion of the left pulmonary veins was found. Here, iodine maps helped in raising conspicuity of loss of lung perfusion.
http://www.ijri.org/currentissue.asp?sabs=y

Pulmonary atresia and ventricular septal defect,Coronary artery as the primary source of pulmonary blood flow

Collateral or fistula? Coronary artery as the primary source of pulmonary blood flow in a patient with pulmonary atresia and ventricular septal defect p. 433
Anurag Yadav, Salil Bhargava, T B S Buxi, Krishna Sirvi
DOI:10.4103/ijri.IJRI_489_17  
In patients with pulmonary atresia and ventricular septal defect (PA/VSD), a coronary artery being the primary source of pulmonary blood flow is a rare entity. We describe two cases of PA/VSD with coronary-to-pulmonary artery fistula with emphasis on the role of Computed Tomographic Angiography (CTA) in depicting all the sources of pulmonary blood supply, to predict surgical management and need for unifocalization of Major Aortopulmonary Collateral Arteries (MAPCA's).
http://www.ijri.org/currentissue.asp?sabs=y

An accurate tool to detect cardiac amyloidosis

Myocardial nulling pattern in cardiac amyloidosis on time of inversion scout magnetic resonance imaging sequence – A new observation of temporal variability p. 427
Harshavardhan Mahalingam, Binita Riya Chacko, Aparna Irodi, Elizabeth Joseph, Leena R Vimala, Viji Samuel Thomson
DOI:10.4103/ijri.IJRI_84_18  
Context: The pattern of myocardial nulling in the inversion scout sequence [time of inversion scout (TIS)] of cardiac magnetic resonance imaging (MRI) is an accurate tool to detect cardiac amyloidosis. The pattern of nulling of myocardium and blood at varying times post gadolinium injection and its relationship with left ventricular mass (LVM) in amyloidosis have not been described previously. Aims: The aim is to study the nulling pattern of myocardium and blood at varying times in TIS and assess its relationship with LVM and late gadolinium enhancement (LGE) in amyloidosis. Materials and Methods: This was a retrospective study of 109 patients with clinical suspicion of cardiac amyloidosis who underwent MRI. Of these, 30 had MRI features of amyloidosis. The nulling pattern was assessed at 5 (TIS5min) and 10 (TIS10min) minutes (min) post contrast injection. Nulling pattern was also assessed at 3min (TIS3min) in four patients and 7min (TIS7min) in five patients. Myocardial mass index was calculated. Mann-Whitney U test was done to assess statistical difference in the myocardial mass index between patients with and without reversed nulling pattern (RNP) at TIS5min. Results: RNP was observed in 58% at TIS5minand 89.6% at TIS10min. Myocardial mass index was significantly higher in patients with RNP at TIS5min[mean = 94.87 g/m2; standard deviation (SD) =17.63) when compared with patients with normal pattern (mean = 77.61 g/m2; SD = 17.21) (U = 18; P = 0.0351). Conclusion: In cardiac amyloidosis, TIS sequence shows temporal variability in nulling pattern. Earlier onset of reverse nulling pattern shows a trend toward more LVM and possibly more severe amyloid load.
http://www.ijri.org/currentissue.asp?sabs=y

Gujarati hypertensives

: A cross-sectional study p. 153
Jayesh Dalpatbhai Solanki, Hemant B Mehta, Sunil J Panjwani, Hirava B Munshi, Chinmay J Shah
DOI:10.4103/jpp.JPP_59_18  
Objective: To study the effect of different classes and combinations of antihypertensive agents on arterial stiffness and central hemodynamic parameters. Materials and Methods: A cross-sectional study was conducted in 446 treated apparently healthy hypertensives. Oscillometric PWA was performed by Mobil-o-Graph (IEM, Germany) to derive cardiovascular parameters that were further analyzed in groups stratified by antihypertensive used. Study parameters were brachial hemodynamics (blood pressure (BP), heart rate, and rate pressure product); arterial stiffness (augmentation pressure, augmentation index, pulse wave velocity, total arterial stiffness, and pulse pressure amplification); and central hemodynamics (central BP, cardiac output, and stroke work). Statistical significance was kept at P < 0.05. Results: All groups were selected by matching of age, gender, and body mass index. They were comparable with major confounding factors. There was no difference between study parameters in hypertensives taking exclusive angiotensin-converting enzyme inhibitor (ACEI), calcium channel blocker (CCB), or angiotensin II receptor blocker. Multitherapy showed better hemodynamics and monotherapy showed better stiffness parameters. Addition of CCB to ACEI did not make a difference except with diastolic BP. For most comparisons, most of the results lacked statistical significance. Conclusion: Discrete PWA parameters showed no class difference in hypertensives, treated by conventional monotherapy or combination, ACEI appears to be the best drug. This also indicates that early diagnosis and blood pressure control are more important than antihypertensive used.
http://www.jpharmacol.com/currentissue.asp?sabs=y

contrast media-induced nonrenal adverse drug reactions

contrast media-induced nonrenal adverse drug reactions over the last three decades: A systematic review p. 131
Maurizio Sessa, Claudia Rossi, Annamaria Mascolo, Antonella Scafuro, Rosanna Ruggiero, Gabriella di Mauro, Salvatore Cappabianca, Roberto Grassi, Liberata Sportiello, Concetta Rafaniello
DOI:10.4103/jpp.JPP_92_18  
The aim of this study was to investigate the scientific contribution of Italian clinical research for contrast media-induced nonrenal adverse drug reactions over the last three decades. Ovid Embase, Ovid MEDLINE, Web of Science, and Cochrane Methodology Register were used as data sources to identify Italian descriptive studies, observational studies, meta-analyses, and clinical trials assessing contrast media-induced nonrenal adverse drug reactions as a safety outcome. The population of interest was men and women exposed to a contrast medium. Between 1990 and 2017, 24 original articles investigating contrast-induced nonrenal adverse drug reactions were identified. The cohort study was the most representative study design (10/24; 41.7%). The 24 studies were conducted mainly as monocenter studies (14/24; 58.3%) and without receiving funding (17/24; 70.8%). Seventeen out of 24 studies provided a level of evidence ranging from III-2 (11/24; 45.8%) to IV (6/24; 25.0%) on a Merlin scale. In total, 14 of 24 (58.3%) studies were published in a scientific journal ranked in the first quartile of their subject area. The 24 original articles mainly focused on adverse drug reactions already observed during clinical trials (i.e., idiosyncratic systemic reactions). In conclusion, during the last three decades and a burst was not observed in the Italian clinical research investigating contrast-induced nonrenal adverse drug reactions. High-quality clinical research is needed especially for procedures to prevent the onset of the aforementioned events, to identify risk factors, to minimize the risk of their occurrence, and to optimize their related prognosis.
http://www.jpharmacol.com/currentissue.asp?sabs=y