Πέμπτη 25 Ιανουαρίου 2018

Adding sufentanil to ropivacaine in continuous thoracic paravertebral block fails to improve analgesia after video-assisted thoracic surgery: A randomised controlled trial

wk-health-logo.gif

BACKGROUND The benefit of adding opioid to a local anaesthetic for continuous thoracic paravertebral analgesia after video-assisted thoracic surgery (VATS) is unclear. OBJECTIVES To analyse the analgesic efficacy of ropivacaine and sufentanil in combination compared with ropivacaine alone after VATS. DESIGN A randomised, double-blinded, single-centre clinical trial. SETTING A tertiary university hospital between March 2010 and April 2014. PATIENTS Ninety patients were recruited, two were not included leaving 88 randomised into two groups. Eighteen patients were excluded from analysis and 70 completed the study. INTERVENTION To receive thoracic paravertebral analgesia with either 2 mg ml−1 ropivacaine and 0.25 μg ml−1 sufentanil (ropivacaine + sufentanil group) or 2 mg ml−1 ropivacaine alone (ropivacaine group) for 48 h postoperatively. Infusion rate was set at 0.15 ml kg−1 h−1 in both groups. MAIN OUTCOME MEASURES The primary endpoint was the mean total amount of self-administered morphine by the patients in each group at 48 h postoperatively. RESULTS The mean ± SD total amount of self-administered morphine was not significantly different between groups (53.1 ± 27.2 mg in the ropivacaine + sufentanil group vs. 58.8 ± 34.3 mg in the ropivacaine group; P = 0.72). No significant differences were found between the two groups in either in pain scores at rest or during movement, in opioid-related adverse reactions, in patient satisfaction or length of hospital stay. CONCLUSION Adding 0.25 μg ml−1 sufentanil to 2 mg ml−1 ropivacaine in continuous thoracic paravertebral analgesia for VATS did not reduce morphine consumption or pain scores when compared with ropivacaine alone. We cannot recommend its use for routine clinical practice. Further studies analysing different concentrations and infusion rates of sufentanil are needed before a lack of efficacy can be confirmed. TRIAL REGISTRATION Clinical trial registrations: EudraCT: 2009-014832-38. ClinicalTrials.gov: NCT 01082744. Correspondence to Christian Bauer, MD, Hospices Civils de Lyon, Hôpital de la Croix Rousse, Service d'Anesthésie-Réanimation, 103 grande rue de la Croix-Rousse, 69004 Lyon, France Tel: +33 426732660; e-mail: christian.bauer@chu-lyon.fr Supplemental digital content is available for this article. Direct URL citations appear in the printed text and are provided in the HTML and PDF versions of this article on the journal's Website (http://ift.tt/2ylyqmW). © 2018 European Society of Anaesthesiology

http://ift.tt/2FkWhq2

Comparison of double intravenous vasopressor automated system using nexfin versus manual vasopressor bolus administration for maintenance of haemodynamic stability during spinal anaesthesia for caesarean delivery: A randomised double-blind controlled trial

BACKGROUND Hypotension is a common side effect of spinal anaesthesia during caesarean delivery and is associated with maternal and foetal adverse effects. We developed an updated double intravenous vasopressor automated (DIVA) system that administers phenylephrine or ephedrine based on continuous noninvasive haemodynamic monitoring using the Nexfin device. OBJECTIVE The aim of our present study is to compare the performance and reliability of the DIVA system against Manual Vasopressor Bolus administration. DESIGN A randomised, double-blind controlled trial. SETTING Single-centre, KK Women's and Children's Hospital, Singapore. PATIENTS Two hundred and thirty-six healthy women undergoing elective caesarean delivery under spinal anaesthesia. MAIN OUTCOME MEASURES The primary outcome was the incidence of maternal hypotension. The secondary outcome measures were reactive hypertension, total vasopressor requirement and maternal and neonatal outcomes. RESULTS The DIVA group had a significantly lower incidence of maternal hypotension, with 39.3% (46 of 117) patients having any SBP reading less than 80% of baseline compared with 57.5% (65 of 113) in the manual vasopressor bolus group (P = 0.008). The DIVA group also had fewer hypotensive episodes than the manual vasopressor bolus group (4.67 versus 7.77%; P 

http://ift.tt/2FkWdGO

Colorectal Cancer:

Publication date: Available online 20 January 2018
Source:Surgical Oncology Clinics of North America
Author(s): Nathan C. Hall, Alexander T. Ruutiainen

Teaser

Progressive technological advancements in imaging have significantly improved the preoperative sensitivity for the detection of very small foci of regionally- or hematogenously-metastatic colorectal cancer. Unfortunately, this information has not translated to continued linear gains in patient survival, and might even result in the false-positive upstaging of some cases: these are two conundrums in the imaging of colorectal cancer. Both conundrums might be resolved by the widespread use of real-time imaging guidance during operative procedures. This might open the way for the widespread use of fluorodeoxyglucose PET/CT for the initial staging of patients with colorectal cancer.


http://ift.tt/2E6ZPMV

Computed tomography and magnetic resonance imaging evaluation of pelvic lymph node metastasis in bladder cancer

Abstract

Background

Accurate evaluation of lymph node metastasis in bladder cancer (BCa) is important for disease staging, treatment selection, and prognosis prediction. In this study, we aimed to evaluate the diagnostic accuracy of computed tomography (CT) and magnetic resonance imaging (MRI) for metastatic lymph nodes in BCa and establish criteria of imaging diagnosis.

Methods

We retrospectively assessed the imaging characteristics of 191 BCa patients who underwent radical cystectomy. The data regarding size, shape, density, and diffusion of the lymph nodes on CT and/or MRI were obtained and analyzed using Kruskal–Wallis test and χ2 test. The optimal cutoff value for the size of metastatic node was determined using the receiver operating characteristic (ROC) curve analysis.

Results

A total of 184 out of 3317 resected lymph nodes were diagnosed as metastatic lymph nodes. Among 82 imaging-detectable lymph nodes, 51 were confirmed to be positive for metastasis. The detection rate of metastatic nodes increased along with more advanced tumor stage (P < 0.001). Once the ratio of short- to long-axis diameter ≤ 0.4 or fatty hilum was observed in lymph nodes on imaging, it indicated non-metastases. Besides, lymph nodes with spiculate or obscure margin or necrosis indicated metastases. Furthermore, the short diameter of 6.8 mm was the optimal threshold to diagnose metastatic lymph node, with the area under ROC curve of 0.815.

Conclusions

The probability of metastatic nodes significantly increased with more advanced T stages. Once lymph nodes are detected on imaging, the characteristic signs should be paid attention to. The short diameter > 6.8 mm may indicate metastatic lymph nodes in BCa.



from Cancer via ola Kala on Inoreader http://ift.tt/2rJ5BC5
via IFTTT

Computed tomography and magnetic resonance imaging evaluation of pelvic lymph node metastasis in bladder cancer

Abstract

Background

Accurate evaluation of lymph node metastasis in bladder cancer (BCa) is important for disease staging, treatment selection, and prognosis prediction. In this study, we aimed to evaluate the diagnostic accuracy of computed tomography (CT) and magnetic resonance imaging (MRI) for metastatic lymph nodes in BCa and establish criteria of imaging diagnosis.

Methods

We retrospectively assessed the imaging characteristics of 191 BCa patients who underwent radical cystectomy. The data regarding size, shape, density, and diffusion of the lymph nodes on CT and/or MRI were obtained and analyzed using Kruskal–Wallis test and χ2 test. The optimal cutoff value for the size of metastatic node was determined using the receiver operating characteristic (ROC) curve analysis.

Results

A total of 184 out of 3317 resected lymph nodes were diagnosed as metastatic lymph nodes. Among 82 imaging-detectable lymph nodes, 51 were confirmed to be positive for metastasis. The detection rate of metastatic nodes increased along with more advanced tumor stage (P < 0.001). Once the ratio of short- to long-axis diameter ≤ 0.4 or fatty hilum was observed in lymph nodes on imaging, it indicated non-metastases. Besides, lymph nodes with spiculate or obscure margin or necrosis indicated metastases. Furthermore, the short diameter of 6.8 mm was the optimal threshold to diagnose metastatic lymph node, with the area under ROC curve of 0.815.

Conclusions

The probability of metastatic nodes significantly increased with more advanced T stages. Once lymph nodes are detected on imaging, the characteristic signs should be paid attention to. The short diameter > 6.8 mm may indicate metastatic lymph nodes in BCa.



http://ift.tt/2rJ5BC5

Immune gene expression and response to chemotherapy in advanced breast cancer

Immune gene expression and response to chemotherapy in advanced breast cancer

Immune gene expression and response to chemotherapy in advanced breast cancer, Published online: 25 January 2018; doi:10.1038/bjc.2017.446

Immune gene expression and response to chemotherapy in advanced breast cancer

http://ift.tt/2rH4J0v

Immune gene expression and response to chemotherapy in advanced breast cancer

Immune gene expression and response to chemotherapy in advanced breast cancer

Immune gene expression and response to chemotherapy in advanced breast cancer, Published online: 25 January 2018; doi:10.1038/bjc.2017.446

Immune gene expression and response to chemotherapy in advanced breast cancer

from Cancer via ola Kala on Inoreader http://ift.tt/2rH4J0v
via IFTTT