Abstract
Background
To evaluate the dosimetric performance of multi-channel vaginal cylinder (MCVC) against interstitial brachytherapy (ISBT) for the treatment of vaginal tumors.
Methods
Vaginal tumors with extension of > 0.5 cm and ≤ 2 cm from the lateral vaginal wall and/or ≤ 1 cm in height above the vaginal vault were retrospectively selected from a ISBT registry trial database. The selected patients were treated with ISBT and targets included the intermediate (IRCTV) or high-risk (HRCTV) clinical target volumes. For technique comparison, a 35 mm MCVC was registered with the interstitial intra-vaginal cylinder. Bladder and rectum contours were transferred from the ISBT to the MCVC-BT plans. Vaginal mucosa was achieved by 3 mm uniform expansion from cylinder surface. Both the ISBT and MCVC-BT plans were optimized using the Inverse Planning Simulated Annealing optimization algorithm. After normalizing target D90 to 700 cGy, dose to organs at risk were measured and compared between ISBT and MCVC plans.
Results
Six interstitial patient plans met the inclusion criteria for this study. Four patients had vaginal primaries and two recurrent cancers in the vagina. Lower doses to bladder and rectum were seen with ISBT plans. In half of the MCVC plans, the rectal dose met the recommended constraints. For plans in which the rectal constraint was not met, the target volumes were abutting the rectum and had a cranial-caudal length ≥ 5 cm. Dose to vaginal mucosa was lower in ISBT plans directed to the HRCTVs, although no difference was seen in circumferential IRCTVs.
Conclusions
Overall, ISBT results in decreased dose to OARs as compared to MCVC. However, MCVC BT results in acceptable doses to OARs with possible improvement in vaginal doses for circumferential targets. Careful consideration to tumor geometry and location may help guide optimal techniques in vaginal tumor brachytherapy.
from Cancer via ola Kala on Inoreader http://ift.tt/2rytpDQ
via IFTTT
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου