Improved lung recruitment and oxygenation during mandatory ventilation with a new expiratory ventilation assistance device: A controlled interventional trial in healthy pigs

BACKGROUND In contrast to conventional mandatory ventilation, a new ventilation mode, expiratory ventilation assistance (EVA), linearises the expiratory tracheal pressure decline. OBJECTIVE We hypothesised that due to a recruiting effect, linearised expiration oxygenates better than volume controlled ventilation (VCV). We compared the EVA with VCV mode with regard to gas exchange, ventilation volumes and pressures and lung aeration in a model of peri-operative mandatory ventilation in healthy pigs. DESIGN Controlled interventional trial. SETTING Animal operating facility at a university medical centre. ANIMALS A total of 16 German Landrace hybrid pigs. INTERVENTION The lungs of anaesthetised pigs were ventilated with the EVA mode (n=9) or VCV (control, n=7) for 5 h with positive end-expiratory pressure of 5 cmH2O and tidal volume of 8 ml kg−1. The respiratory rate was adjusted for a target end-tidal CO2 of 4.7 to 6 kPa. MAIN OUTCOME MEASURES Tracheal pressure, minute volume and arterial blood gases were recorded repeatedly. Computed thoracic tomography was performed to quantify the percentages of normally and poorly aerated lung tissue. RESULTS Two animals in the EVA group were excluded due to unstable ventilation (n=1) or unstable FiO2 delivery (n=1). Mean tracheal pressure and PaO2 were higher in the EVA group compared with control (mean tracheal pressure: 11.6 ± 0.4 versus 9.0 ± 0.3 cmH2O, P  0.99). Minute volume was lower in the EVA group compared with control (5.5 ± 0.2 versus 7.0 ± 1.0 l min−1, P = 0.02) with normoventilation in both groups (PaCO2 5.4 ± 0.3 versus 5.5 ± 0.3 kPa, P > 0.99). In the EVA group, the percentage of normally aerated lung tissue was higher (81.0 ± 3.6 versus 75.8 ± 3.0%, P = 0.017) and of poorly aerated lung tissue lower (9.5 ± 3.3 versus 15.7 ± 3.5%, P = 0.002) compared with control. CONCLUSION EVA ventilation improves lung aeration via elevated mean tracheal pressure and consequently improves arterial oxygenation at unaltered positive end-expiratory pressure (PEEP) and peak inspiratory pressure (PIP). These findings suggest the EVA mode is a new approach for protective lung ventilation. This is an open access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (CCBY-NC-ND), where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal. https://ift.tt/OBJ4xP Correspondence to Johannes Schmidt, MD, Department of Anesthesiology and Critical Care, Medical Centre – University of Freiburg, Faculty of Medicine, University of Freiburg, Hugstetter Str. 55, 79106 Freiburg, Germany Tel: +49 761 270 26390; fax: +49 761 270 23280; e-mail: johannes.schmidt@uniklinik-freiburg.de Supplemental digital content is available for this article. Direct URL citations appear in the printed text and are provided in the HTML and PDF versions of this article on the journal's Website (https://ift.tt/2ylyqmW). © 2018 European Society of Anaesthesiology

https://ift.tt/2HUTrNU

Δεν υπάρχουν σχόλια:

Δημοσίευση σχολίου