Τετάρτη 4 Ιουλίου 2018

Can visual analogue scale be used in radiologic subjective image quality assessment?

Abstract

Background

Assessment of qualitative or subjective image quality in radiology is traditionally performed using a fixed-point scale even though reproducibility has proved challenging.

Objective

Image quality of 3-T coronary magnetic resonance (MR) angiography was evaluated using three scoring methods, hypothesizing that a continuous scoring scale like visual analogue scale would improve the assessment.

Materials and methods

Adolescents corrected for transposition of the great arteries with arterial switch operation, ages 9–15 years (n=12), and healthy, age-matched controls (n=12), were examined with 3-D steady-state free precession magnetic resonance imaging. Image quality of the coronary artery origin was evaluated by using a fixed-point scale (1–4), visual analogue scale of 10 cm and a visual analogue scale with reference points (figurative visual analogue scale). Satisfactory image quality was set to a fixed-point scale 3=visual analogue scale/figurative visual analogue scale 6.6 cm. Statistical analysis was performed using Cohen kappa coefficient and agreement index.

Results

The mean interobserver scores for the fixed-point scale, visual analogue scale and figurative visual analogue scale were, respectively, in the left main stem 2.8, 5.7, 7.0; left anterior descending artery 2.8, 4.7, 6.6; circumflex artery 2.5, 4.5, 6.2, and right coronary artery 3.2, 6.3, 7.7. Scoring with a fixed-point scale gave an intraobserver κ of 0.52–0.77 while interobserver κ was lacking. For visual analogue scale and figurative visual analogue scale, intraobserver agreement indices were, respectively, 0.08–0.58 and 0.43–0.71 and interobserver agreement indices were up to 0.5 and 0.65, respectively.

Conclusion

Qualitative image quality evaluation with coronary 3-D steady-state free precession MR angiography, using a visual analogue scale with reference points, had better reproducibility compared to a fixed-point scale and visual analogue scale. Image quality, being a continuum, may be better determined by this method.